7MF4033-ABCDE-FGHI
|
HART
|
|
CODE B : PRESSURE RANGE
|
|
B
|
0.01 ... 1 bar g
|
|
C
|
0.04 ... 4 bar g
|
|
D
|
0.16 ... 16 bar g
|
|
E
|
0.63 ... 63 bar g
|
|
F
|
1.6 ... 160 bar g
|
|
G
|
4.0 ... 400 bar g
|
|
J
|
7,0 ... 700 bar g
|
|
CODE C : Wetted parts materials for seal and connection
|
|
A
|
Stainless steel+Stainless steel
|
|
B
|
Hastelloy+Stainless steel
|
|
C
|
Hastelloy+Hastelloy
|
|
Y
|
Version as diaphragm seal
|
|
CODE D : Process connection
|
|
0
|
Connection shank G½B to EN 837-1
|
|
1
|
Female thread ½-14 NPT
|
|
2
|
Mounting thread 7/16-20 UNF to EN 61518
|
|
3
|
Mounting thread M10 to DIN 19213
|
|
4
|
Mounting thread M12 to DIN 19213
|
|
5
|
Male thread M20 x 1,5
|
|
6
|
Male thread ½-14 NPT
|
|
CODE E : Non-wetted parts materials
|
|
0
|
Housing made of die-cast aluminium
|
|
3
|
Housing stainless steel precision casting4)
|
|
CODE F :Version
|
|
A
|
Standard version
|
|
B
|
International version, English label inscriptions,
|
|
CODE A : Measuring cell & cleaning
|
|
1
|
Silicone oil+Standard
|
3
|
Inert liquid1)+Grease-free
|
CODE G : Explosion protection
|
|
A
|
Without
|
|
B
|
Intrinsic safety (EEx ia)"
|
|
D
|
Explosion-proof (EEx d)"
|
|
P
|
Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"
|
|
E
|
Ex nA/nL (zone 2)"
|
|
R
|
Intrinsic safety, explosion-proof enclosure and EEx ia + EEx d +Zone 1D/2D
|
|
NC
|
Intrinsic safety and explosion-proof With FM + CSA
|
|
CODE H : Electrical connection / cable entry
|
|
A
|
Screwed gland Pg 13.5 (adapter)
|
|
B
|
Screwed gland M20x1.5
|
|
C
|
Screwed gland ½-14 NPT
|
|
D
|
Han 7D plug (plastic housing) incl.mating connector
|
|
F
|
M12 connector (metall)
|
|
CODE I : DISPLAY
|
|
0
|
Without indicator
|
|
1
|
Without visible digital indicator & DIGITAL indicator hidden
|
|
6
|
With visible digital indicator, setting: mA
|
|
7
|
with customer-specific digital indicator with order code Y21 & Y22
|
|
|
|
|
|
|